medimarket.com logo

Support tel: +36-53/200108

Categories
medimarket.com logo

Support tel: +36-53/200108

  • Categories
    • Products on sale
    • All Products
    • Disease Treatment
    • Devices by Treatment Purpose
    • Fitness
    • Rehabilitation equipment
    • Beauty Care
    • Clinic Equipment
    • Accessories and Add-Ons
    • Symptoms A-Z
    • Veterinary Medicine
    • Clearance Sale
  • Info
  • Become our Distributor
  • Become our Affiliate
M-Sonic 950 Therapeutic Ultrasound Device
M-Sonic 950 Therapeutic Ultrasound Device
169.00 €
  1. Therapeutic Ultrasound
  1. All Products
  2. Therapeutic Ultrasound

M-Sonic 950 Therapeutic Ultrasound Device

Article No.: 
UT1032
CE / MDR
Popular!
Therapeutic
Nu-Tek
M-Sonic 950 Therapeutic Ultrasound Device
Instruction for Use

Download: Instruction for use

In stock
169.00 €

M-Sonic 950: therapeutic ultrasound /1MHz /6.4W /1.6W/cm² /3 intensity levels /continuous CW and pulsed PW modes.
Price includes: 1× M-Sonic 950 device | 1× power adapter | 1× carrying bag

Csomagajánlatok
Compatible accessories
Details

The M-Sonic 950 is a modern, portable ultrasound therapeutic device. Its primary purpose is pain relief and therapy for muscle tension as well as joint contractures. Thanks to its compact design and ergonomic shape, the device is comfortable to hold and easy to use both at home and in professional settings.

M-Sonic 950 Operating Principle and Therapeutic Effects

The device uses 1 MHz frequency ultrasound, which penetrates deeply into the tissues. Ultrasound waves produce mechanical vibrations that have multiple beneficial effects on the treated area.

One of the most important effects is increased local blood flow, which causes vasodilation. The increased circulation helps reduce inflammatory processes and speeds up healing.

Most patients do not feel much sensation during treatment, though some report mild warmth, a natural consequence of the enhanced blood supply to the tissues.

The M-Sonic 950 operates on three different intensity levels: low (L), medium (M), and high (H). The low setting has a 5% duty cycle, medium 50%, and high 100% modulation cycle time.

This allows for personalized treatment and gradual intensity increase according to patient needs.

The device’s maximum output power is 6.4W, which is sufficient for therapeutic effects while remaining safe.

Applications and Therapeutic Benefits

Ultrasound treatment is especially effective for various musculoskeletal issues.

It is excellent for alleviating chronic pain, such as lower back pain, neck pain, or arthritis.

It also plays a significant role in relieving muscle spasms, as the ultrasound penetrating deeper tissues can reduce muscle tension.

Additionally, it can be effective in treating joint contractures by improving tissue elasticity and enhancing range of motion.

This therapy is particularly useful for athletes who often suffer from muscle tension or minor injuries. Treatment can accelerate regeneration and shorten rehabilitation time.

Moreover, the device features a head warming function that enhances comfort during treatment by preheating the ultrasound head, providing a more pleasant sensation for the patient.

Safe Use and Contraindications

While the M-Sonic 950 is generally safe, there are specific conditions and situations where its use is contraindicated.

  • Not to be used on pregnant women over the abdominal area.
  • Use is prohibited over malignant tumors and surrounding areas.
  • Cannot be used on patients with pacemakers in the chest region.
  • Avoid use over growth zones of bones until bone growth completion.
  • Use caution in patients with bleeding disorders or areas with blood clots.
  • Prohibited for use around and directly over the eyes.
  • Not recommended during acute illnesses, fever, tuberculosis, or facial paralysis.
  • Avoid ultrasound therapy on surgical sites, open wounds, or burned skin.

Treatment Process and Proper Use

Successful and safe therapy requires proper preparation and adherence to correct protocols.

First, clean the treatment area thoroughly to remove any dirt and oily substances.

Then, apply a generous amount of ultrasound gel, which acts as a coupling medium between the ultrasound head and the skin. Gel usage is essential because, without it, ultrasound waves cannot properly penetrate the tissues.

After turning on the device, the head warming feature activates automatically, taking about three minutes. This preheating ensures comfortable treatment and optimal efficiency.

Treatment duration can be set to 5, 10, or 15 minutes using the "TIME" button.

It's advisable to start at the lower intensity level and gradually increase as needed.

During treatment, move the ultrasound head in continuous circular motions over the target area. Ensure smooth movement and constant proper contact with the skin. The device has a built-in contact sensor that immediately signals if contact is interrupted.

For safety, the device includes a temperature protection function that automatically stops the treatment if the temperature exceeds 42°C.

Maintenance and Care

Regular maintenance is essential for the device’s long lifespan and reliable operation.

After each use, clean the ultrasound head with a damp cloth or soft rag. Use lukewarm water and non-abrasive household cleaners. For enhanced disinfection, antimicrobial wipes (Clinell device disinfecting wipes) can be used.

Never immerse the device in liquid. While the ultrasound head is IPX7 rated, the entire device is not waterproof.

Regularly inspect the applicator for hairline cracks that may allow fluid penetration. Also clean and check cables and power adapter for damage.

Recommendation

The M-Sonic 950 is a versatile and effective therapeutic device offering a safe solution for various musculoskeletal problems when used properly.

Its ease of use and portability allow application both at home and in professional environments.

The different intensity levels and treatment times allow therapy customization.

Consult a doctor before starting therapy, especially if you have chronic illness or other health issues. Follow the precautions and contraindications described in the user manual. Regularly monitor therapy effectiveness and any side effects. Discontinue use and consult a professional if discomfort occurs.

Proper maintenance and storage significantly extend device lifespan and ensure continued reliable operation. The two-year warranty provides extra user security but is valid only with correct use and adherence to the user manual instructions.

Info
Weight:
750 g/pcs
Similar products
Video

Watch Dr. Zsolt Zátrok's video about the M-Sonic 950 device and general use.

 

Technical Specifications

Technical Specifications

  • Ultrasound frequency: 1.0 MHz ± 10%
  • Treatment area: 4 cm²
  • Power density: 1.6 W/cm²
  • Max. power: 6.4 W (continuous mode)
  • Output power:
    • L: 0.32 W ± 20%
    • M: 3.20 W ± 20%
    • H: 6.40 W ± 20%
  • Duty cycle: L (5%), M (50%), H (100%)

M-Sonic 950 Features

The M-Sonic 950 uses advanced technology for effective treatment. It operates at 1 MHz ± 10%, ideal for therapeutic effect. Maximum power is 6.4 W ± 20%, with a 4.0 cm² radiating surface. Three power levels - low (0.32 W), medium (3.20 W), high (6.40 W) - offer flexibility.

Dimensions: 202 × 49 × 70 mm; weight: 193 g (without adapter). The aluminum alloy applicator ensures durability and efficient ultrasound transmission. Class II device with BF type applied parts.

Electromagnetic Compatibility and Safety

The M-Sonic 950 complies with IEC 60601-1-2 standards. Do not use near other electronic devices (e.g. ECGs), even if EMC compliant. Maintain at least 2 m distance from shortwave equipment. Use only the manufacturer's supplied adapter (100-240 V 50/60 Hz input; 15 V DC max. 1.2 A output). The device has no battery and operates only on mains power.

Opinions
Be the first to review this product!
Review
Customer account
  • Login
  • Registration
  • Profile
  • Basket
  • Favorites
Information
  • General terms and conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact Us
Scart Ltd
  • Koltói Anna utca 39., Albertirsa, 2730
  • +36-53/200108
  • info@medimarket.com
  • facebook

Other information
  • Exchange and Returns
  • Service and Warranty
  • Become a Distributor
  • Become our Affiliate
barion_com
paypal
  • Products on sale
  • All Products
  • Disease Treatment
  • Devices by Treatment Purpose
  • Fitness
  • Rehabilitation equipment
  • Beauty Care
  • Clinic Equipment
  • Accessories and Add-Ons
  • Symptoms A-Z
  • Veterinary Medicine
  • Clearance Sale
  • Info
  • Become our Distributor
  • Become our Affiliate
Change language
  • hu
  • en
  • sk
  • de
Change currency
Login
Register
Cookie settings
Our website uses cookies that are essential for basic operation. You can enable marketing related cookies for broader functionality. In this case you also accept the privacy policy
Cookies are crucial to the essential functionality of the website and the website will not function properly without them. These cookies do not store personally identifiable information.
We use marketing cookies to track visitors' website activity. The aim is to serve relevant ads to individual users (e.g. Google Ads, Facebook Ads) and to encourage activity, which makes our website more valuable.
By collecting and reporting data in an anonymous form, statistical cookies help the website owner to understand how visitors interact with the website.
Cookies used for personalisation allow us to remember information that changes the way a website behaves or looks.