Soccer Pro TENS/EMS/MCR device 4 channels
Soccer Pro TENS/EMS/MCR device 4 channels
409.00 €
  1. Electrotherapy
  1. All Products
  2. Electrotherapy

Soccer Pro TENS/EMS/MCR device 4 channels

Article No.: 
G5084
4 channels
CE / MDR
Popular!
GLOBUS
Soccer Pro TENS/EMS/MCR device 4 channels
Instruction for Use

Download: Instruction for use

In stock
409.00 €

Soccer Pro: multifunctional electrotherapy device. TENS /EMS /MCR-MENS /FES /iontophoresis. Special: soccer. 4 channels, battery-powered.
Price includes: Soccer Pro device, 4 colored cables, 2 cables for microcurrent treatment, 4 pcs 50x50mm and 4 pcs 50x90mm TENS electrodes, battery charger, carrying bag

Sport :
Cycling
Running
Soccer
Triathlon
Multisport
Csomagajánlatok
Compatible accessories
Details

Soccer Pro: multifunctional electrotherapy device with TENS | EMS | MENS | MCR | FES | Iontophoresis programs

The device's hundreds of programs can aid in treating, improving, healing, or preventing thousands of issues.

  • Disease treatments: Pain relief, muscle condition improvement, anti-inflammation, circulation improvement, edema reduction, deep delivery of active substances, post-surgery and disease rehabilitation
  • Programs for sports preparation and muscle regeneration, injury treatment and prevention
  • Body shaping and fitness programs. Diet support, post-pregnancy body recovery assistance.
  • Beauty care through muscle condition and skin elasticity improvement. Professional microcurrent skin treatments.

Read Dr. Zsolt Zátrok's article about the Soccer Pro device.

Treatment types

The device is multifunctional, providing multiple electrical treatment modes. Each mode applies to solving different problems.

TENS

TENS, transcutaneous electrical nerve stimulation, is mainly suitable for musculoskeletal pain relief. It can also be used for menstrual pain and to a lesser extent, cancer pain reduction.

EMS or NMES

Electrical muscle stimulation referred to as EMS or NMES in medical practice. Used for muscle-related problems. Main applications include muscle stiffness, muscle atrophy, slowing muscle strength and mass loss, improving blood circulation, and reducing muscle pain. When applied before musculoskeletal surgery, it improves surgical outcomes and is essential post-surgery rehabilitation support.

FES

FES or functional electrical stimulation is usually marked as a separate treatment mode. It is also muscle stimulation, done here for regaining some lost abilities.

After central paralysis, muscles may partially regain movement within days (in fortunate cases) but become clumsy and weak. Functional stimulation is muscle stimulation performed for strength recovery and relearning movements.

MENS or MCR

Microcurrent is an extremely mild current (TENS or muscle stimulation current is about a thousand times stronger).

Microcurrent can be used for pain relief (called MENS – microcurrent nerve stimulation) or healing (called MCR).

Microcurrent accelerates healing of inflammatory processes (including gingivitis, arthritis, arthrosis, etc.). It reduces edema, making it useful in acute treatment of herniated discs, lumbago, sciatica, and other radicular symptoms. It speeds healing of injuries, wounds, muscle tears, etc.

Microcurrent stimulates collagen production and with that, wound and scar healing – applicable also in beauty care, effective in restoring skin elasticity and wrinkle treatments.

Iontophoresis

Iontophoresis is a current type useful for treating joint inflammations, sports injuries. It allows delivery of a (water-soluble, electrically charged) drug through the skin directly to the affected area, avoiding the digestive system. For example, in ankle injury, orally taken drugs distribute throughout the body with only a minimal amount reaching the ankle. It should be the opposite: much to the ankle, little to the rest. Iontophoresis helps this.

Program groups

  • Medical treatments
    • 12 TENS programs - pain reduction
    • 23 Microcurrent (MENS and MCR). Pain and inflammation reduction treatment, healing stimulating effect
    • 3 rehabilitation programs for supporting recovery after knee surgeries
    • 1 iontophoresis treatment program. Mainly for accelerating joint injury healing (iontophoresis kit not included)
  • Fitness and body shaping -58 programs for shaping, toning, general fitness support
  • Beauty care - 36 beauty care treatments
  • G-Pulse professional microcurrent beauty care - 13 professional cosmetic programs for the special G-Trode applicator (applicator sold separately)
  • 3S sequential stimulation - 18 programs for neurorehabilitation, edema treatment, regeneration improvement
  • Sport - 53 program variants. Development of muscle fiber specific skills, muscle regeneration, capillarization, warm-up.
  • Special sport - 32 developmental programs optimized for soccer players
  • ActionNow programs - 7 instant start programs combining exercise practice and muscle stimulation

Special programs supporting soccer preparation

  • Applicable for professional and amateur soccer players, regardless of the position.
  • Physical preparation programs aim to develop long-term strength of muscles involved in soccer movements, prevent joint and muscle injuries, and reduce risk factors.
  • Enhancing explosiveness for sprinting, improving directional change speed, improving jump height.
  • Improving and maintaining endurance during prolonged effort.
  • Improving agonist/antagonist muscle balance.
  • Goalkeeper training programs for improving reaction time and explosiveness.
  • Separate programs are available for "support muscles" such as upper limb muscles and core muscles.
  • Preventive programs aim to reduce muscle bruises and stiffness, as well as treat joint and ligament injuries and inflammations.
  • Programs aimed at improving regeneration speed up lactic acid and metabolite clearance. This relaxes tight, tense ligaments and muscles, accelerates muscle regeneration and fatigue elimination.

Useful functions

Function

Details

last10.jpgLAST 10 function:
The device stores the last 10 executed programs. They can be quickly and easily selected and started from this list.
autostim.jpgAUTO STIM function
Allows automatic execution of a program without intensity adjustment. The intensity is set according to the last execution of the program. AUTO STIM is only available for TENS and EMS programs recorded in the "Last 10" memory.
runtime.jpgRun Time function
Allows modification of main parameters during an ongoing program: treatment time, frequency, pulse duration. Pressing the Function button activates editing.
favourities.jpgFavorite programs
Allows saving most used programs (max. 15 per user) in memory for quick start.
stimlock.jpgSTIM LOCK function
Allows locking programs saved in the Treatments menu. Important when lending to patients who must only run "locked" programs set by the therapist (without access to other programs).
easyprogram.jpgCreate own program
Allows creating and modifying up to 15 new programs, making the device extremely flexible and customizable to individual needs.
2plus2.jpg2+2 mode
Allows simultaneous execution of two different programs (EMS or TENS). Thus, two patients or two muscle groups can be treated together. Programming of channels 1-2 and 3-4 can be separated.
multiuser.jpgMultiuser
Allows multi-user, personalized usage. To access Favorites and Last10 functions, the user must log into their profile. Treatment plans can be set for up to 10 users.

Contraindications for electrical treatment

Electrotherapy treatments (TENS, EMS, MENS, FES, ETS, CES, microcurrent, iontophoresis, denervated, selective current, Kotz, interferential, etc.) are safe and free of side effects.

There are only a few conditions contraindicating usage.

Currently, electrotherapy treatment is PROHIBITED for patients with pacemakers or implanted defibrillators. Other conditions are not exclusion criteria but require weighing pros and cons by the physician.

If unsure about applicability, read Dr. Zsolt Zátrok's article on the Lifelong Healthy blog. Click here.

It is often believed that electrotherapy devices cannot be used with metal implants, prostheses, bone plates, screws. This is outdated. Read Dr. Zsolt Zátrok's article on implant and electrical treatment interaction. Click here.

Info
Field of application :
Pain relief, Muscle therapy, Recovery, Joint pain, Anti-inflammatory, Stimulate circulation, Central palsy, Beauty care (EMS), Beauty care (MCR)
EAN:
8032625826798
Sport :
Soccer
Treatment type :
TENS, MENS/MCR, EMS/NMES, Iontophoresis
Weight:
1.2 kg/db
Similar products
Video
Technical data

Technical data

  • Hungarian language menu system and Hungarian user manual.
  • Very simple and clear to use.
  • Other languages available: English, German, French, Italian, Spanish. Pre-set treatment programs.
  • 2+2 function (different programs can be run on 2-2 channels, e.g., you can treat both knee and neck pain simultaneously)
  • Backlit display
  • Feedback mechanism: detects patient contact - treatment can only start if electrodes are touching
  • Device size: 160x99x35.4 mm
  • Weight: 404 g
  • Protection level: IP 22
  • Storage and transport temperature: -10°C - 45°C
  • Storage and transport relative humidity: 30% - 75%

Operating conditions

  • Temperature: 0°C - 35°C
  • Max. relative humidity: 15% - 93%
  • Atmospheric pressure: 700 hPa - 1060 hPa
  • Battery mode: 7.2V, 1.8Ah rechargeable Ni-MH battery with charger
  • For safety, no treatment can start when device connected to mains charger (switch on also blocked)
  • Mains mode: 100-240Vac 50-60Hz Max 0.6A

TENS and EMS current characteristics

  • Biphasic, compensated, symmetric square wave (signal quality constant from positive to negative pole, no polarization effect)
  • Available on any of channels 1-4
  • Constant current generator guarantees steady current regardless of skin condition, and stops current if electrode detaches
  • Intensity: 0-120 mA, 1000 Ohm
  • Frequency: 0.3-150 Hz
  • Pulse amplitude (pulse duration): 50-450 μs
  • Work time: 1 - 30 seconds
  • Rest time: 0 - 1 minute
  • Frequency modulation range: continuously adjustable between 1 - 150 Hz
  • Minimum modulation time: 3 seconds
  • Amplitude modulation range: continuously adjustable between 50 - 450 milliseconds

 

Microcurrent

  • Available channels: 1st and 3rd channels
  • Min. frequency: 5Hz
  • Max. frequency: 200Hz
  • Min. intensity: 0 μA/1000 Ohm, 10 μA steps
  • Max. intensity: 800 μA/1000 Ohm
  • Amplitude (pulse duration) varies between 1 - 250 milliseconds

 

Iontophoresis

  • Available channel: 1st channel
  • Continuous current: Yes
  • Min. intensity: 0 mA/1000 Ohm
  • Max. intensity: 10 mA/1000 Ohm steps of 0.1 mA/1000 Ohm

 

Adjustable treatment time

  • Min. time: 1 minute
  • Max. time: 99 minutes

 

Opinions
Be the first to review this product!
Review
Customer account
  • Login
  • Registration
  • Profile
  • Basket
  • Favorites
Information
  • General terms and conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact Us
Scart Ltd
  • Koltói Anna utca 39., Albertirsa, 2730
  • +36-53/200108
  • info@medimarket.com
  • facebook

Other information
  • Exchange and Returns
  • Service and Warranty
  • Become a Distributor
  • Become our Affiliate
barion_com
paypal
  • Products on sale
  • All Products
  • Disease Treatment
  • Devices by Treatment Purpose
  • Fitness
  • Rehabilitation equipment
  • Beauty Care
  • Clinic Equipment
  • Accessories and Add-Ons
  • Symptoms A-Z
  • Veterinary Medicine
  • Clearance Sale
  • Info
  • Become our Distributor
  • Become our Affiliate
Change language
  • hu
  • en
  • sk
  • de
Change currency
Login
Register
Cookie settings
Our website uses cookies that are essential for basic operation. You can enable marketing related cookies for broader functionality. In this case you also accept the privacy policy
Cookies are crucial to the essential functionality of the website and the website will not function properly without them. These cookies do not store personally identifiable information.
We use marketing cookies to track visitors' website activity. The aim is to serve relevant ads to individual users (e.g. Google Ads, Facebook Ads) and to encourage activity, which makes our website more valuable.
By collecting and reporting data in an anonymous form, statistical cookies help the website owner to understand how visitors interact with the website.
Cookies used for personalisation allow us to remember information that changes the way a website behaves or looks.