Personal-Laser L200
Personal-Laser L200
1 155.00 €
  1. Softlaser devices
  1. Home therapy
  2. Softlaser devices

Personal-Laser L200

Item number: 
ELPL200
CE / MDR
Class 3 Laser
Energy-Laser
Personal-Laser L200
Available to order
For order
1 155.00 €

Do you have a non-healing wound, scar, skin problem or tinnitus? The Personal Laser L200 medical soft laser with a 660 nm red beam can help support the natural regeneration of skin and superficial tissues at home, pain-free. Class 3B, CE IIa certified medical device. 200 mW continuous power, 12 Joule/min energy output. Protective goggles and an aluminium carry case are included.

 

Bundle offers
Compatible accessories
Details
Dr. Zsolt Zátrok
Doctor Our medical expert says

Dr. Zsolt Zátrok
Physician, medical technology expert, blogger | Registration number: 49381/1

“The Personal Laser L200 stands out in the entry-level medical laser category. A 660 nm wavelength together with 200 mW power is an ideal combination for treating superficial tissues – skin, scars, superficial joints. Manufactured in Denmark, CE IIa medical certification, a true diode laser. Many people also use it successfully as an adjunct for tinnitus. If you want a compact, portable solution for complaints close to the skin surface, this device is an excellent choice.”

What can you use it for?

Sound familiar? A small cut, abrasion or surgical wound – and weeks later it still hasn’t closed properly. This is especially frustrating with diabetes, circulation problems or simply slow healing.

The 660 nm red laser light is absorbed in the upper layers of the skin, where it may support cellular metabolic processes. Systematic reviews and meta-analyses show that LLLT treatment can statistically significantly aid wound healing in skin wounds (Khoja et al., 2024 – PubMed).

Tip: Hold the laser about 1 cm from the wound, treat each area for 30–60 seconds, once daily. For scars, a longer course (2–4 weeks) is recommended.

Sound familiar? Small joint inflammation – in the finger, ankle or wrist – is especially annoying because every movement reminds you of it. Anti-inflammatory creams only help temporarily, and you may not want to take pills long-term.

Photobiomodulation (PBM) may reduce inflammatory processes by increasing mitochondrial activity. The 660 nm wavelength penetrates about 1–2 cm, which is suitable for reaching superficial structures of small joints, fingers, wrists and ankles (Glass, 2021 – PubMed).

Tip: Treat the inflamed joint 1–2 times daily for 1–2 minutes. Pain relief is typically expected after 1–2 weeks of regular use.

Sound familiar? You switch off the light and it’s quiet – but there is noise in your head. Persistent tinnitus can impair sleep, concentration and quality of life.

Transmeatal application of soft laser is one of the most studied adjunctive treatments for tinnitus. Clinical trials used 660 nm lasers at 100–200 mW power in the ear canal. Results are mixed – some studies show improvement, others find no significant difference from placebo (Chen et al., 2020 – PubMed). The L200 settings match those used in the research.

Tip: Hold the laser at the entrance of the ear canal; a daily 10–15 minute treatment is recommended. Wear protective goggles during use. Several weeks of treatment are needed to evaluate any effect.

Sound familiar? A surgical scar is thickening instead of fading. Cold sore blisters keep returning at the worst times. An ingrown toenail keeps getting inflamed.

The 660 nm red laser is an optimal wavelength for skin tissues. Research suggests it may support collagen production, which can contribute to scar fading and improved elasticity. For herpes, early laser treatment in the blister stage is reported to help speed resolution.

Tip: Treat scars for 1 minute daily for 4–6 weeks. For cold sores, apply the laser twice daily for 30–60 seconds during the blister stage.

Sound familiar? Your pet was injured, had surgery, or has chronic skin problems – and healing is slower than you’d like.

Soft laser therapy is widely used in veterinary medicine. The 660 nm wavelength is suitable for superficial tissues in small animals – wounds, sutures, skin inflammations. Consult your veterinarian for a treatment protocol.

Tip: Trim hair from the treated area. Hold the laser 1 cm from the skin and treat each area for 30–60 seconds daily. Make sure the animal does not look into the laser beam!

Frequently asked questions

Yes, the device has CE IIa medical device certification. Protective goggles are included and must be worn during every treatment. Never point the laser directly at the eye or at reflective surfaces. Follow the treatment times and contraindications in the user manual.

The L200 operates at 660 nm (red) with 200 mW power – this is ideal for superficial treatments (wounds, scars, skin, tinnitus). The L400 uses an 808 nm (infrared) wavelength at 400 mW – it penetrates deeper tissues (joints, tendons, muscles). If you need a solution for issues close to the skin surface, the L200 is the better choice. For deeper pain (knee, back, shoulder), the L400 is more effective.

A treatment typically takes 1–5 minutes per area. The device delivers about 12 Joule per minute. Most superficial treatments recommend 4–12 Joule, which is about 30–60 seconds. For tinnitus, a 10–15 minute session is recommended. One battery charge gives roughly 3 hours of use.

A real Class 3B diode laser, not an LED. A diode laser is coherent and emits a single wavelength (660 nm), delivering energy more targeted and deeper than scattered LED light. This is an important distinction from a medical perspective. More: LED lamp or diode laser – what is the difference?

For acute complaints (fresh injuries, cold sores) use 1–2 times daily. For chronic problems (scars, tinnitus) once daily is sufficient. Improvement is usually noticed after 1–2 weeks of regular use. Detailed protocols are in the soft laser therapy guide.

How to use it? It’s that simple:

1

Put on the protective goggles

Always wear the protective goggles included in the package during every treatment. A Class 3B laser can cause eye injury from direct or reflected beams.

2

Switch on the laser

Press the power button. The device is ready immediately – no warm-up time, no complicated settings.

3

Hold it to the treatment area

Keep the laser about 0.5–1 cm from the skin surface. Move slowly or hold on one spot for 30–60 seconds. The device delivers about 12 Joule per minute.

4

Repeat regularly

Regular daily treatment is key. Most complaints require a 1–4 week course, once or twice daily. Specific protocols are in the user manual and the soft laser therapy guide.

What’s in the package?

  • 1 x Personal Laser L200 device (aluminium housing)
  • 1 x lithium-ion battery (3.7 V)
  • 1 x battery charger + USB cable + USB mains adapter
  • 1 x protective goggles (mandatory!)
  • Aluminium carry case
  • User manual

The Personal Laser L200 is a Class 3B medical laser. This means direct or reflected beams can injure the eye. Always wear the protective goggles included in the package – even when you treat your legs or hands.

The premium aluminium carry case stores the device, charger and goggles. Ideal for travel – the laser stays protected from damage.

Warning When NOT to use the device?

  • Do not use over malignant tumours (cancerous areas)
  • Do not use on the abdomen or uterus during pregnancy
  • Do not apply if you have photosensitivity
  • Never aim at the eye or directly at the eyeball – always wear protective goggles!
  • Consult a physician if you have epilepsy
  • Do not use on actively bleeding areas

Warning Important information

The device may be used as an adjunct treatment alongside physician-prescribed therapy. It does not replace medical examination or treatment. Consult your treating physician if you have complaints!

Technical specifications

Specification Value
Wavelength 660 nm (visible red light)
Maximum power (CW) 200 mW continuous mode
Penetration depth approx. 1–2 cm
Energy output approx. 12 Joule/min
Beam area 1 cm²
Operation mode Continuous (CW – Continuous Wave)
Laser class 3B (medical)
Battery Li-Ion, 3.7 V – approx. 3 hours runtime
Weight 42 g
Material Aluminium housing
CE certification Class IIa LLLT medical device (MDR)
Manufacturer Akeda Laser ApS (Denmark)
Eye protection Protective goggles included (mandatory wear)

Scientific background

Selected scientific publications supporting the device’s mechanism of action:

  1. Khoja A et al. (2024): The Effects of Low-Level Laser Therapy on Wound Healing and Pain Management in Skin Wounds: A Systematic Review and Meta-Analysis. Cureus, 16(11):e74385. PubMed
    Result: Significant improvement in wound healing (95% CI 13.93–37.70, p<0.0001) and pain reduction (VAS -2.52 – -0.19, p=0.02).
  2. Glass GE (2021): Photobiomodulation: The Clinical Applications of Low-Level Light Therapy. Aesthetic Surgery Journal, 41(6):723–738. PubMed
    Result: A comprehensive review of clinical applications of LLLT for wound healing, analgesia and anti-inflammatory effects.
  3. Zein R, Selting W, Hamblin MR (2018): Review of light parameters and photobiomodulation efficacy: dive into complexity. Journal of Biomedical Optics, 23(12):120901. PubMed
    Result: Critical review of wavelength, power and dose parameters – 660 nm is optimal for superficial tissue applications.
  4. Chen Y et al. (2020): Efficacy of Low-Level Laser Therapy for Tinnitus: A Systematic Review with Meta-Analysis. Ear, Nose & Throat Journal, 101(5):NP212–NP220. PubMed
    Result: Mixed outcomes – no significant difference from placebo in pooled analysis (MD -2.85, 95% CI -8.99 – 3.28, p=0.362).
  5. Zadik Y et al. (2019): Tumor safety and side effects of photobiomodulation therapy: A systematic review. Oral Oncology, 93:21–28. PubMed
    Result: PBM therapy appears safe and did not increase tumour growth risk at the parameters studied to date.

Learn more

  • GuideSoft laser therapy – comprehensive guide to home laser treatment →
  • Laser devicesSoft laser devices →
  • LED vs LaserLED lamp or diode laser – what is the difference? →
  • ContraindicationsSoft laser therapy contraindications and safety information →
  • TinnitusTinnitus and soft laser therapy →
  • HerpesSoft laser treatment for cold sores →
  • Scar treatmentSoft laser treatment for scars and keloids →
  • L400Personal Laser L400 – for deeper treatments →
Data
Downloadable files:
Instruction for Use
Article recommendation :
Laser device and therapy
Brand:
Energy-Laser
CE certification :
CE certified
Wavelength :
660nm
Mode of operation :
folyamatos (CW)
Area :
1cm2
Energy input :
12.0
Peak power :
200mW
Eye protection :
javasolt - védőszemüveg az árban
Manufacturer :
AKEDA Sp. z o.o.
Website:
https://energy-laser.dk
Similar products
Reviews
Be the first to write a review!
Write a review
Customer account
  • Sign In
  • Sign Up
  • My Profile
  • Cart
  • My Favorites
Information
  • Terms and Conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact details
Scart Kft
  • Koltói Anna utca 39., Albertirsa, 2730
  • +36-53/200108
  • [email protected]
  • facebook

barion_com
paypal
  • Deals
  • Home therapy
  • Disease Treatment
  • Fitness
  • Beauty Care
  • Veterinary Medicine
  • Clinic Equipment
  • Accessories and Add-Ons
  • Clearance Sale
  • Blog
  • Info
  • About us
Change language
  • hu
  • en
  • sk
  • de
  • nl
Change currency
Sign in
Sign Up
Privacy settings
Our website uses cookies necessary for basic functionality. You can allow additional cookies for broader features (marketing, analytics, personalization). For more details, see our Privacy Policy in the Privacy Notice.