medimarket.com logo

Support tel: +36-53/200108

Categories
medimarket.com logo

Support tel: +36-53/200108

  • Categories
    • Products on sale
    • All Products
    • Disease Treatment
    • Devices by Treatment Purpose
    • Fitness
    • Rehabilitation equipment
    • Beauty Care
    • Clinic Equipment
    • Accessories and Add-Ons
    • Symptoms A-Z
    • Veterinary Medicine
    • Clearance Sale
  • Info
  • Become our Distributor
  • Become our Affiliate
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
577.00 €
  1. Softlaser device
  1. All Products
  2. Softlaser device

B-Cure Laser Classic softlaser (LLLT)

Article No.: 
7290014180000
CE / MDR
Popular!
Class 1 Laser
B-Cure
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
B-Cure Laser Classic softlaser (LLLT)
Instruction for Use

Download: Instruction for use

In stock
577.00 €

B-Cure Laser Classic is a home softlaser device

Who do we recommend it for?

  • People with musculoskeletal pain
  • Those seeking a solution for pain relief

How does it help?

  • Relieves neck and shoulder pain
  • Treats lower back and back complaints
  • Alleviates minor joint inflammations
  • Soothes strains
  • Pain relief after dental treatments
  • Effective for mild sports injuries and muscle soreness

Package includes:

  • 1 piece of B-Cure Laser Classic device
  • Carrying bag
  • 1 power adapter
  • 3 AAA NiMH rechargeable batteries (1.2V, 850mAh)
Model version, The B-Cure laser range includes several devices that are identical in form but emit a laser beam of different intensity. The higher energy allows for shorter treatment times and more effective therapeutic effects. Model version :
Classic
Sport Pro
Pro
Csomagajánlatok
Compatible accessories
Details

Operating principle and technology

The B-Cure Classic operates with a GaAIAs (gallium-aluminum-arsenide) solid-state laser diode emitting an 808 nanometer wavelength infrared laser beam.

This specially calibrated laser beam operates at a maximum power of 250 mW and a pulse frequency of 11.7 kHz, optimal for tissue regeneration and pain relief.

The device delivers 4.2 joules of energy per minute to the treated area, scientifically proven to stimulate the cells' natural healing processes.

Applications

Orthopedic applications

The B-Cure Classic is particularly effective in treating various musculoskeletal problems. It is successfully used for chronic back and lower back pain, with treatments along the spine in a longitudinal direction. For neck pain treatment, therapy can be applied both beside the vertebrae and on the lateral parts of the neck.

Joint problems

The device is excellent for joint pain.

It can be used on all joints, for example, treating various points of the knee (back of the knee crease, as well as outer and inner sides). For shoulder joint issues, in addition to direct treatment of painful areas, surrounding tissues can also be treated for better results.

Special conditions

The device is also effective for specific conditions such as carpal tunnel syndrome, where various directions of treatment on the inner wrist side can be combined. For fibromyalgia and myofascial pain syndrome, targeted treatment of painful areas can be performed.

Treatable conditions with softlaser

Musculoskeletal origin conditions

  • Acute and chronic pain of bones, joints, and tissues
  • Joint capsule and partial ligament tears
  • Lower back, thoracic, neck, and other muscle pains
  • Low back pain, sciatica caused by herniated disc
  • Pain and osteoarthritis in knee, hip, shoulder, hand, and toe joints
  • Rheumatic pain (rheumatoid arthritis) and/or chronic tendon inflammation
  • Tendon, tendon sheath, and muscle inflammations due to overexertion
  • Heel bone spurs and sprains
  • Tennis elbow and golfer's elbow
  • Achilles tendonitis, wrist-tendon sheath inflammation
  • Carpal tunnel syndrome (wrist pain) - Carpal tunnel syndrome (CTS)
  • Myofascial pain syndrome

Skin conditions

  • Stimulating wound healing
  • Hard-to-heal wounds, ulcers
  • Diabetic ulcers
  • Acne - pimply skin
  • Fresh scars and burns
  • Scar improvement and pain relief of scars
  • Promotes better and more aesthetic healing of surgical scars
  • Cold sores, shingles
  • Eczema

Dental complaints

  • Gum and tooth root inflammation
  • Any oral mucosal inflammation
  • Inflammation reduction and healing stimulation after tooth extraction or dental surgery
  • Treatment of temporomandibular joint inflammation and pain

Maintenance and care

The device requires minimal maintenance, but to ensure long life, some basic rules must be followed. The laser beam outlet must be regularly cleaned with 70% alcohol solution, especially if the device is used by multiple users. During cleaning, take care that the lens does not get wet. Store the device in a dry, cool place, protected from direct sunlight and extreme temperatures.

Safety and contraindications

The B-Cure Classic is an extremely safe device with virtually no contraindications. However, some important safety instructions must be followed:

  • Do not aim the laser beam into the eyes
  • Not to be used on the abdominal area during pregnancy
  • Not to be used near active malignant tumors
  • Treatment must be applied directly on the skin surface

Technical specifications

  • Laser type: GaAIAs solid-state laser diode
  • Maximum power: 250 mW
  • Wavelength: 808 nm (infrared)
  • Pulse frequency: 11.7 kHz
  • Laser pulse duration: 24.5 μs
  • Diode lifetime: 1000 hours
  • Energy per minute: 4.2 joule

The device has practical usage parameters:

  • Timer setting range: 00:00 - 99:30 minutes
  • LCD display size: 26 x 15 mm
  • Power supply: 3 AAA rechargeable batteries
  • Battery life: 2 hours at full charge
  • Charging time: 5-7 hours
  • Operating temperature: 0°C - 40°C
  • Humidity tolerance: 15-90% (non-condensing)

The device has a compact and portable design:

  • Dimensions: 200 x 70 x 40 mm
  • Weight: 175 grams
  • Laser beam size: 45 x 10 mm at the aperture
Info
EAN:
7290014180000
Model version :
Classic
Weight:
520 g/db
Similar products
Application

Performing softlaser treatment

  • Place the device on the painful area and hold it for the prescribed time.
  • If the area is larger than the treatment head coverage, treat each point consecutively until the entire area is covered.
  • Treat 2-4 times daily until full recovery (at least 10 days recommended).
  • For fresh injuries, up to 10 treatments may be performed on the first day.
  • Laser therapy must be applied directly on the skin; it is ineffective through clothes or bandages.
  • If direct contact is not possible (e.g., burn or ulcer), keep the device as close to the skin as possible.

Treatment points

General softlaser treatment pointsB-Cure-laser-therapy-points.jpg

Treatment points for sports injuriesB-Cure-Sport-laser-therapy-points.jpg

Dental laser treatment pointsB-Cure-dental-treatment-points.jpg

Treatment protocol

The B-Cure Classic is extremely easy and safe to use. Its interface features an LCD display and simple buttons. Treatment time is adjustable in 30-second increments, and an automatic timer signals the end of treatment with a beep.

Treatment times and frequency

For chronic pain, start with shorter 1.5-minute treatments, then gradually increase to 6-8 minutes.

Treatments can be repeated 2-4 times daily. In acute pain, the full duration can be used from the first session onwards.

The laser covers a 4.5 x 1 cm area; for larger areas, treat in sections. Always place the device on the skin and keep it still during treatment. Effective treatment cannot be performed through clothing or bandages.

Video

Watch Dr. Zsolt Zátrok's videos about softlasers and the most important considerations before choosing a device.

Watch Dr. Zsolt Zátrok's video on B-Cure softlasers.

Opinions
Be the first to review this product!
Review
Customer account
  • Login
  • Registration
  • Profile
  • Basket
  • Favorites
Information
  • General terms and conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact Us
Scart Ltd
  • Koltói Anna utca 39., Albertirsa, 2730
  • +36-53/200108
  • info@medimarket.com
  • facebook

Other information
  • Exchange and Returns
  • Service and Warranty
  • Become a Distributor
  • Become our Affiliate
barion_com
paypal
  • Products on sale
  • All Products
  • Disease Treatment
  • Devices by Treatment Purpose
  • Fitness
  • Rehabilitation equipment
  • Beauty Care
  • Clinic Equipment
  • Accessories and Add-Ons
  • Symptoms A-Z
  • Veterinary Medicine
  • Clearance Sale
  • Info
  • Become our Distributor
  • Become our Affiliate
Change language
  • hu
  • en
  • sk
  • de
Change currency
Login
Register
Cookie settings
Our website uses cookies that are essential for basic operation. You can enable marketing related cookies for broader functionality. In this case you also accept the privacy policy
Cookies are crucial to the essential functionality of the website and the website will not function properly without them. These cookies do not store personally identifiable information.
We use marketing cookies to track visitors' website activity. The aim is to serve relevant ads to individual users (e.g. Google Ads, Facebook Ads) and to encourage activity, which makes our website more valuable.
By collecting and reporting data in an anonymous form, statistical cookies help the website owner to understand how visitors interact with the website.
Cookies used for personalisation allow us to remember information that changes the way a website behaves or looks.