M-Sonic 950 Therapeutic Ultrasound Device
M-Sonic 950 Therapeutic Ultrasound Device
169.00 €
  1. Therapeutic Ultrasound
  1. All Products
  2. Therapeutic Ultrasound

M-Sonic 950 Therapeutic Ultrasound Device

Article No.: 
UT1032
CE / MDR
Popular!
Therapeutic
Nu-Tek
M-Sonic 950 Therapeutic Ultrasound Device
Instruction for Use

Download: Instruction for use

In stock
169.00 €

M-Sonic 950 therapeutic ultrasound device.

What is it used for?

  • Relieving chronic pain (lower back pain, neck pain or joint inflammations)
  • Muscle spasm relief
  • Effective in treating joint contractures as well
  • Muscle tension or minor sports injuries.
  • May accelerate regeneration and reduce rehabilitation time

Price includes:

  • M-Sonic 950 device (1 pcs)
  • Power adapter (1 pcs)
  • Carrying bag (1 pcs)
Csomagajánlatok
Compatible accessories
Details

The M-Sonic 950 is a modern, portable ultrasound device for compression therapy. Its primary purpose is pain relief and therapy of muscle tension and joint contractures. The device is compact and ergonomically designed, making it comfortable to hold and easy to use both at home and in professional environments.

Areas of application and therapeutic benefits

Ultrasound therapy is particularly effective for many musculoskeletal issues.

It is excellent for relieving chronic pain, such as lower back pain, neck pain, or joint inflammations.

It plays a significant role in relieving muscle spasms by reducing muscle tension with ultrasound waves penetrating deep tissues.

It can also be effective in treating joint contractures by improving tissue elasticity and increasing range of motion.

The therapy is especially useful for athletes who often suffer from muscle tension or minor injuries. Treatment can speed up regeneration and reduce rehabilitation time.

Additionally, the device features a head-warming function that enhances comfort by preheating the ultrasound head, providing a more pleasant sensation for the patient.

Safe use and contraindications

While the M-Sonic 950 is generally a safe device, there are conditions and situations where its use is contraindicated.

  • Treatment is not applicable on the abdomen of pregnant women.
  • Use is forbidden on malignant tumors and their vicinity.
  • Must not be used on patients with pacemakers in the chest region.
  • Avoid use over bone growth zones until growth is complete.
  • Exercise particular caution in patients with bleeding disorders or areas with blood clots.
  • Use around and directly above the eyes is prohibited.
  • Treatment is not recommended during acute illnesses, fever, tuberculosis, or facial paralysis.
  • Avoid use on surgical sites, open wounds, or burnt skin.

Treatment process and proper use

Successful and safe treatment requires proper preparation and adherence to usage protocols.

First, clean the treatment area, removing any dirt or oily substances.

Then, apply a generous amount of ultrasound gel to the area to serve as a conductive medium between the ultrasound head and the skin. Gel use is crucial for proper ultrasound penetration.

After turning on the device, the head-warming function activates automatically, taking about three minutes. This preheating ensures comfortable treatment and optimal effectiveness.

The treatment time can be set to 5, 10, or 15 minutes using the "TIME" button.

When selecting intensity, it is advisable to start low and increase gradually if needed.

During the treatment, move the ultrasound head continuously in circular motions over the treated area, ensuring even movement and consistent contact with the skin. The device has a built-in contact sensor that alerts if contact is lost.

For safety, the device includes temperature protection that automatically stops treatment above 42°C.

Maintenance and care

Regular maintenance is necessary to ensure long service life and reliable operation.

After each use, clean the ultrasound head with a damp cloth or soft rag. Mild household cleaners and lukewarm water can be used. For stronger disinfection, cloths impregnated with antimicrobial cleaner such as Clinell device disinfectant wipes are suitable.

Never immerse the device in liquid. Though the ultrasound head is IPX7 protected, the full device is not waterproof.

Regularly inspect the applicator for hairline cracks that might allow liquid ingress. Also clean and check cables and adapter for damage.

M-Sonic 950 operating principle and therapeutic effects

The device uses 1 MHz ultrasound which penetrates deep into tissues. The ultrasound waves generate mechanical vibrations providing multiple benefits at the treatment site.

One of the main effects is increased local blood flow causing vasodilation. This supports reduction of inflammation and speeds healing.

Most patients feel no strong sensation during treatment, though some report mild warmth from increased blood flow.

The M-Sonic 950 operates at three intensity levels: low (L), medium (M), and high (H). Low uses a 5% modulation cycle, medium 50%, and high 100%, allowing personalized therapy and gradual intensity adjustment according to patient needs.

Maximum output power is 6.4W, sufficient for therapeutic effect yet safe.

Recommendations

The M-Sonic 950 is a versatile and effective therapy device offering safe treatment for various musculoskeletal problems when used properly.

Its simple operation and portability allow use both at home and in professional settings.

Different intensity levels and treatment durations enable therapy customization.

Consult a doctor before starting treatments, especially if you have chronic diseases or other health issues. Follow safety warnings and contraindications in the user manual. Monitor treatment effectiveness and side effects. Stop treatment and seek professional advice if discomfort occurs.

Proper maintenance and storage significantly prolong the device's life and ensure continuous reliable function. The 2-year warranty offers extra user security but applies only when adhering to user guide instructions.

Info
Weight:
750 g/pcs
Similar products
Video

Watch Dr. Zsolt Zátrok's video about the M-Sonic 950 device and its general use.

Technical specifications

Technical specifications

  • Ultrasound frequency: 1.0 MHz ± 10%
  • Treatment area: 4 cm²
  • Power density: 1.6 W/cm²
  • Max. power: 6.4 W (continuous mode)
  • Output power:
    • L: 0.32 W ± 20%
    • M: 3.20 W ± 20%
    • H: 6.40 W ± 20%
  • Operating cycle: L (5%), M (50%), H (100%)

M-Sonic 950 features

The M-Sonic 950 employs advanced technology for effective treatment. It operates at 1 MHz ± 10%, ideal for therapeutic effects. Maximum power is 6.4 W ± 20%, with a 4.0 cm² radiator surface. Three power levels - low (0.32 W), medium (3.20 W), high (6.40 W) - provide flexibility.

Dimensions: 202 × 49 × 70 mm, weight 193 g (without adapter). Aluminum alloy applicator ensures durability and effective ultrasound transmission. Class II device with BF applied parts.

Electromagnetic compatibility and safety

The M-Sonic 950 complies with IEC 60601-1-2 standards. Do not use near other electronic devices (e.g., ECGs) even if EMC compliant. Maintain at least 2 m distance from shortwave equipment. Use only manufacturer-supplied adapter (100-240 V 50/60 Hz input; 15 V DC max. 1.2 A output). The device has no battery and operates only on mains power.

Opinions
Be the first to review this product!
Review
Customer account
  • Login
  • Registration
  • Profile
  • Basket
  • Favorites
Information
  • General terms and conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact Us
Scart Ltd
  • Koltói Anna utca 39., Albertirsa, 2730
  • +36-53/200108
  • info@medimarket.com
  • facebook

Other information
  • Exchange and Returns
  • Service and Warranty
  • Become a Distributor
  • Become our Affiliate
barion_com
paypal
  • Products on sale
  • All Products
  • Disease Treatment
  • Devices by Treatment Purpose
  • Fitness
  • Rehabilitation equipment
  • Beauty Care
  • Clinic Equipment
  • Accessories and Add-Ons
  • Symptoms A-Z
  • Veterinary Medicine
  • Clearance Sale
  • Blog
    Blog
    • Disease and Its Symptoms
    • Training and Injuries
    • Lifestyle
    • FAQ
    • Device and Equipment
    • Rehabilitation
    • Therapy and Treatment
  • Info
  • Become our Distributor
  • Become our Affiliate
Change language
  • hu
  • en
  • sk
  • de
Change currency
Login
Register
Cookie settings
Our website uses cookies that are essential for basic operation. You can enable marketing related cookies for broader functionality. In this case you also accept the privacy policy
Cookies are crucial to the essential functionality of the website and the website will not function properly without them. These cookies do not store personally identifiable information.
We use marketing cookies to track visitors' website activity. The aim is to serve relevant ads to individual users (e.g. Google Ads, Facebook Ads) and to encourage activity, which makes our website more valuable.
By collecting and reporting data in an anonymous form, statistical cookies help the website owner to understand how visitors interact with the website.
Cookies used for personalisation allow us to remember information that changes the way a website behaves or looks.