Genesy 300 Pro TENS/EMS/MCR Device, 4 channels
Genesy 300 Pro TENS/EMS/MCR Device, 4 channels
409.00 €
  1. Electrotherapy
  1. All Products
  2. Electrotherapy

Genesy 300 Pro TENS/EMS/MCR Device, 4 channels

Article No.: 
G3222
4 channels
CE / MDR
GLOBUS
Genesy 300 Pro TENS/EMS/MCR Device, 4 channels
Instruction for Use

Download: Instruction for use

In stock
409.00 €

Genesy 300 Pro: multifunctional electrotherapy device. TENS /EMS /MCR-MENS /FES /iontophoresis. 4 channels, battery operated.
Price includes: device, 4 cables, 2 cables for microcurrent treatment, 4 pcs 50x50mm and 4 pcs 50x90mm TENS electrodes, battery charger, carrying bag

Csomagajánlatok
Compatible accessories
Details

Genesy 300 Pro: multifunctional electrotherapy device with TENS | EMS | MENS | MCR | FES | Iontophoresis programs

The device's hundreds of programs can help in treating, improving, healing, or preventing numerous issues.

  • Disease treatment: Pain relief, muscle condition improvement, inflammation reduction, circulation enhancement, edema reduction, deep drug delivery, post-surgery and disease rehabilitation
  • Programs aiding sports preparation and muscle regeneration, injury treatment and prevention
  • Body shaping and fitness programs. Supports weight loss and post-pregnancy body recovery.

Treatment types

The device is multifunctional, providing several types of electrical treatments. Each treatment mode is used for different problems.

TENS

TENS, transcutaneous electrical nerve stimulation, is primarily used for relieving musculoskeletal pain. It can also be used for menstrual pain and to a lesser extent for cancer pain reduction.

EMS or NMES

Electrical muscle stimulation is referred to as EMS or NMES in medical practice. It is used for muscle-related issues. Main applications include reducing muscle stiffness, atrophy, slowing decrease in muscle strength and mass, improving blood flow, reducing muscle pain. Pre-surgical preparation improves surgical outcomes, and post-surgery rehabilitation relies heavily on it.

FES

FES or functional stimulation is often identified as a separate treatment mode. In fact, it is muscle stimulation performed to recover lost functions.

After central paralysis, muscles partially regain mobility after a few days (in favorable cases), but become clumsy and weak. Muscle stimulation performed to regain strength and relearn movement is functional stimulation.

MENS or MCR

Microcurrent is an extremely mild current (for example, TENS or muscle stimulation currents are about a thousand times stronger).

Microcurrent can be used for pain relief (MENS - microcurrent nerve stimulation) or healing (MCR).

Microcurrent accelerates healing of inflammatory processes (including tendonitis, arthritis, arthrosis, etc.). It reduces edema, useful in acute treatment of herniated discs, lumbago, sciatica, and other radicular symptoms. It speeds up the healing of injuries, wounds, muscle tears, etc.

Microcurrent stimulates collagen production, promoting healing of wounds and scars - beneficial in cosmetic care, effective in restoring skin elasticity and wrinkle treatment.

Iontophoresis

Iontophoresis is beneficial for treating joint inflammations and sports injuries. It delivers a medicinal substance (dissolved in water and electrically charged) directly to the problematic area through the skin, bypassing the digestive system. This is its advantage. For example, after an ankle injury, oral medication spreads to the entire body, and only a minimal amount reaches the ankle. Ideally, more should reach the ankle and less the rest of the body. Iontophoresis helps achieve this.

Program groups

  • Medical treatments
    • 20 TENS programs
    • 12 Microcurrent (MENS and MCR): pain and inflammation relief, healing stimulation.
    • 7 rehabilitation programs
    • 1 iontophoresis treatment program: mainly accelerating healing of joint injuries (iontophoresis kit not included in the price)
  • Fitness and body shaping 29 programs for body shaping, slimming, general fitness support.
  • Sport - 22 program variants.

Muscle treatment (sport)

  • Active regeneration
  • Endurance strength
  • Warm-up
  • Hypertrophy
  • Capillarization
  • Maximum strength
  • Reaction speed
  • Explosive strength
  • Pre-competition warm-up
  • Post-competition regeneration

Fitness-Body shaping

  • Aerobic training
  • Body shaping
  • Anaerobic training
  • Bio-pulse tightening
  • Bio-pulse shaping
  • Revitalization
  • Tightening
  • Shaping
  • Cramp prevention
  • Jogging
  • Detail sculpting
  • Mass gain

Microcurrent

  • Acute pain
  • Tendon inflammation
  • Sciatica
  • Joint pain
  • Lumbago
  • Stiff neck
  • Whiplash injury
  • Tennis elbow
  • Knee sprain
  • Shoulder-blade periarthritis
  • Shoulder dislocation
  • Bruise

Pain relief (TENS)

  • Low frequency pain relief TENS
  • Bursitis-tendinitis
  • Bone fracture pain
  • Carpal tunnel
  • Endorphin TENS
  • Traditional pain relief TENS
  • Sciatica
  • Muscle pain
  • Chronic pain
  • Chronic lumbago
  • Menstrual pain
  • Modulated pain relief TENS
  • Post-operative pain
  • Neck pain
  • Osteoarthritis
  • Rotator cuff inflammation
  • Tennis elbow
  • Knee pain
  • Trapezius pain

Rehabilitation

  • Recovery after ACL surgery
  • Swollen ankles
  • Functional regeneration
  • Mixed incontinence
  • Quadriceps atrophy
  • Shoulder dislocation prevention
  • Vastus medialis strength recovery

Iontophoresis

Useful features

Feature

Details

last10.jpgLAST 10 feature:
The device stores the last 10 executed programs. They can be quickly and easily selected and started from the list.
autostim.jpgAUTO STIM feature
Allows automatic execution of a program without setting intensity. Intensity is set based on last usage of the program. Only usable with "Last 10" stored TENS and EMS programs.
runtime.jpgRun Time feature
After starting a program, main parameters (time, frequency, pulse duration) can be modified. Pressing the function button opens the modification option.
favourities.jpgFavorite programs
Allows saving frequently used programs (up to 15 per user) in memory for quick start.
stimlock.jpgSTIM LOCK feature
Allows locking programs saved in Treatments menu. Important when lending to patients who must use therapist-locked programs (other programs are disabled).
easyprogram.jpgCreate your own program
Allows creating and modifying up to 15 new programs, making the device very flexible and customizable.
2plus2.jpg2+2 mode
Allows simultaneous execution of two different programs (EMS or TENS). Thus, two patients or two muscle groups can be treated simultaneously. Channels 1-2 and 3-4 are programmable separately.
multiuser.jpgMultiuser
Allows personalized use by multiple users. Favorite and Last10 functions require user profile login. Up to 10 users can have treatment plans.

Contraindications of electrical treatment

Electrotherapy treatments (TENS, EMS, MENS, FES, ETS, CES, microcurrent, iontophoresis, denervated, selective current, Kotz, interferential, etc.) are safe and side-effect-free.

Only a few conditions are contraindications.

Current guideline: ANY electrotherapy treatment is FORBIDDEN for patients with pacemakers or implanted defibrillators. Other conditions are not exclusions; benefits and risks must be weighed by the treating physician.

If unsure about applicability, read Dr. Zsolt Zátrok's article on the Lifetime Health blog. Click here.

Common belief that electrotherapy devices cannot be used with metal implants, prostheses, bone plates, screws is outdated. Read Dr. Zsolt Zátrok's article on implants and electrical treatment Click here.

Info
Field of application :
Pain relief, Muscle therapy, Recovery, Joint pain, Anti-inflammatory, Treatment of incontinence, Stimulate circulation, Central palsy
EAN:
8032625825814
Treatment type :
TENS, MENS/MCR, EMS/NMES, Iontophoresis
Weight:
1.22 kg/db
Similar products
Video



Technical data

Technical data

  • Hungarian language menu system and Hungarian language user manual.
  • Very simple and clear to use.
  • Additional languages available: English, German, French, Italian, Spanish. Pre-set treatment programs.
  • 2+2 feature (different programs on 2-2 channels, e.g., treat knee and neck pain simultaneously).
  • Backlit display
  • Feedback mechanism: detects patient contact - treatment starts only if electrodes connect.
  • Device size: 160x99x35.4 mm
  • Weight: 404 g
  • Protection level: IP 22
  • Storage and transport temperature: -10°C - 45°C
  • Storage and transport relative humidity: 30% - 75%

Operating conditions

  • Temperature: 0°C - 35°C
  • Max. relative humidity: 15% - 93%
  • Atmospheric pressure: 700 hPa - 1060 hPa
  • Battery mode: 7.2V, 1.8Ah rechargeable Ni-MH battery with charger
  • Treatment is not allowed if charger is connected for safety (not even power on)
  • Mains mode: 100-240Vac 50-60Hz Max 0.6A

TENS and EMS current characteristics

  • Biphasic, compensated, symmetric square wave (signal quality constant from positive to negative pole, no polarization effect)
  • Available on any of channels 1-2-3-4
  • Constant current generator ensuring stable current for all skin conditions and stops current if electrodes fall off.
  • Intensity: 0-120 mA, 1000 Ohm
  • Frequency: 0.3-150 Hz
  • Pulse amplitude (pulse duration): 50-450 μs
  • Work time: 1 - 30 seconds
  • Rest time: 0 - 1 minute
  • Frequency modulation range: adjustable continuously between 1 - 150 Hz
  • Min modulation time: 3 seconds
  • Amplitude modulation range: adjustable continuously between 50 - 450 milliseconds

 

Microcurrent

  • Available channels: 1 and 3
  • Min frequency: 5Hz
  • Max frequency: 200Hz
  • Min intensity: 0 μA/1000 Ohm, 10 μA steps
  • Max intensity: 800 μA/1000 Ohm
  • Pulse amplitude (pulse duration): varies between 1 - 250 milliseconds

 

     

    Iontophoresis

    • Available channel: 1
    • Continuous current: Yes
    • Min intensity: 0 mA/1000 Ohm
    • Max intensity: 10 mA/1000 Ohm steps of 0.1 mA/1000 Ohm

     

    Adjustable treatment time

    • Min time: 1 minute
    • Max time: 99 minutes

     

    Opinions
    Be the first to review this product!
    Review
    Customer account
    • Login
    • Registration
    • Profile
    • Basket
    • Favorites
    Information
    • General terms and conditions
    • Privacy Policy
    • Payment
    • Shipping
    • Contact Us
    Scart Ltd
    • Koltói Anna utca 39., Albertirsa, 2730
    • +36-53/200108
    • info@medimarket.com
    • facebook

    Other information
    • Exchange and Returns
    • Service and Warranty
    • Become a Distributor
    • Become our Affiliate
    barion_com
    paypal
    • Products on sale
    • All Products
    • Disease Treatment
    • Fitness
    • Devices by Treatment Purpose
    • Beauty Care
    • Clinic Equipment
    • Accessories and Add-Ons
    • Symptoms A-Z
    • Veterinary Medicine
    • Clearance Sale
    • Info
    • Become our Distributor
    • Become our Affiliate
    Change language
    • hu
    • en
    • sk
    • de
    Change currency
    Login
    Register
    Cookie settings
    Our website uses cookies that are essential for basic operation. You can enable marketing related cookies for broader functionality. In this case you also accept the privacy policy
    Cookies are crucial to the essential functionality of the website and the website will not function properly without them. These cookies do not store personally identifiable information.
    We use marketing cookies to track visitors' website activity. The aim is to serve relevant ads to individual users (e.g. Google Ads, Facebook Ads) and to encourage activity, which makes our website more valuable.
    By collecting and reporting data in an anonymous form, statistical cookies help the website owner to understand how visitors interact with the website.
    Cookies used for personalisation allow us to remember information that changes the way a website behaves or looks.