What treatments can it be used for?
The program library provides starting points for adjunctive treatment of arthrosis, knee osteoarthritis, knee pain, hip pain, ankle sprain, bursitis and other periarticular complaints.
Photobiomodulation can be used to influence pain and symptoms in surrounding soft tissues. It does not restore worn cartilage, the meniscus or a torn ligament, and it does not replace physiotherapy, load modification or orthopedic assessment.
Manufacturer protocols include acute and chronic back pain, lumbar and cervical syndromes, myofascial pain and complaints associated with radiculopathy.
The program name does not replace a diagnosis. For radiating limb pain, muscle weakness, sensory disturbance, urinary or fecal dysfunction, trauma or rapid deterioration, a medical examination is required before treatment.
The program library may include protocols for shoulder pain, frozen shoulder, subacromial bursitis, rotator cuff-related complaints and postoperative rehabilitation.
Laser therapy is an adjunct to rehabilitation. Significant loss of strength, postoperative immobility or suspected full tendon rupture require imaging and specialist assessment.
Epicondylitis, Achilles tendinopathy, patellar tendon complaints, De Quervain’s syndrome, tenosynovitis and trigger point treatment are among the target areas listed in the source.
Tendon rehabilitation is based on load management and gradual strengthening. Pain reduction alone does not mean the tendon is ready for full sports or work loading.
For muscle pain, contracture, contusion, strain, post-injury edema and postoperative rehabilitation, laser can be part of a multimodal treatment plan.
In fresh injuries, first exclude fracture, complete rupture, infection and other urgent conditions. High power is not intended to mask symptoms that prevent safe return to sport.
The plantar fasciitis program provides manufacturer starting points for targeted treatment of painful areas of the plantar fascia.
Laser does not remove a bony heel spur. Treatment aims to complement management of surrounding soft tissues alongside load modification, appropriate footwear and rehabilitation.
The program list includes edema-management protocols for acute injury and postoperative conditions.
Unknown-source swelling should be investigated first. Laser does not replace compression, movement, proper wound care or comprehensive lymphedema therapy.
Clinic use: The portable format is advantageous for mobile practice, sports clubs and working across multiple treatment rooms.
Why choose the PhysioLaser 6.0?
6 W maximum optical power
At maximum continuous output, up to 360 Joules of energy can be delivered per minute. Compared to a 2 W model, the same dose can theoretically be delivered in about one third of the time.
Around 85 clinical protocols
The broader program library provides starting points for joint, spine, tendon, sports-rehabilitation and edema-related treatments.
Portable, approximately 450 g device
The compact central unit, battery operation and carrying bag are practical for therapists working between multiple treatment locations.
11 mm standard optic, 22 mm option
The package includes an 11 mm handpiece. According to the source, a separate 22 mm optic may be available for faster scanning of larger areas.
808 nm standard, optional additional handpieces
The package contains an 808 nm handpiece. 980 and 1064 nm handpieces are optional accessories; their compatibility and performance should be checked separately.
Two protective goggles and emergency stop
Operator and patient laser-protective goggles required for Class 4 treatment, plus a safety emergency-stop switch, are included in the package.
Is the PhysioLaser 6.0 right for you?
Around 85 built-in clinical protocols
The protocols listed in the source mainly cover musculoskeletal, sports-rehabilitation and edema-related treatments. Program selection simplifies setup but does not replace diagnosis, dose verification or treatment documentation.
Arthrosis, knee osteoarthritis, acute and chronic knee pain, hip pain, ankle sprain with edema, bursitis, meniscal-related complaints, postoperative joint conditions and further manufacturer protocols.
The list summarizes program groups given in the source. Exact program names and parameters should be checked in the device menu and user manual.
Acute and chronic back pain, lumbago, lumbar syndrome, radiculopathy-related back pain, spondylosis, myofascial back pain and postoperative complaints.
The list summarizes program groups given in the source. Exact program names and parameters should be checked in the device menu and user manual.
Acute and chronic neck pain, cervical syndrome, myofascial neck pain, shoulder pain, frozen shoulder, rotator cuff-related complaints, bursitis and postoperative shoulder treatment.
The list summarizes program groups given in the source. Exact program names and parameters should be checked in the device menu and user manual.
Epicondylitis, Achilles tendinopathy, patellofemoral tendinopathy, De Quervain’s syndrome, tenosynovitis, carpal tunnel syndrome, trigger points and plantar fasciitis.
The list summarizes program groups given in the source. Exact program names and parameters should be checked in the device menu and user manual.
Edema associated with acute injury, DOMS, muscle contracture, contusion, strain, postoperative pain, rehabilitation phases, adjunctive treatment for fibromyalgia and other sports-medical protocols.
The list summarizes program groups given in the source. Exact program names and parameters should be checked in the device menu and user manual.
Optional handpieces: the standard package contains the 808 nm head. The 980 and 1064 nm heads’ availability, power, program compatibility and eye-protection requirements should be checked separately.
What does 6 W laser treatment mean?
During photobiomodulation, light of a defined wavelength and dose is delivered to the target tissue. The biological response depends on wavelength, power, energy dose, spot size, pulse settings and treatment geometry.
6 W maximum power in continuous mode equals 6 Joules per second, i.e. up to 360 Joules per minute. This enables fast dose delivery but requires increased attention to tissue heating and avoiding excessive dosing.
The standard 808 nm handpiece operates in the near-infrared range. Optional 980 and 1064 nm handpieces may have different tissue absorption properties, but they should not be simply ranked as "deeper" or automatically more effective wavelengths.
The portable format does not reduce Class 4 safety requirements.
Professional treatment in four steps
Examine the patient
Clarify the diagnosis, treatment goal, tissue condition and contraindications. The program name must not be used instead of a diagnosis.
Select the protocol and verify the dose
Check wavelength, power, mode, frequency, duty cycle, treatment time, spot size and the size of the area to be treated.
Ensure a Class 4 environment
The operator and patient must wear appropriate certified laser-protective goggles for the used wavelength. Remove reflective objects, prevent unauthorized entry and keep the emergency stop accessible.
Perform and document the treatment
For point treatment keep the handpiece stable; for scanning move at an even speed. Document the treated area, parameters, energy dose and patient response.
Frequently asked questions
6 W is the maximum nominal optical power. At maximum continuous operation this means up to 360 Joules per minute energy delivery. In pulsed programs the average energy delivery may be lower.
The main advantage of higher power is faster dose delivery. Penetration is also determined by wavelength, tissue optical properties, spot size, contact and treatment geometry; 6 W alone does not imply three times the penetration depth.
Yes. The device is a Class 4 laser. Both operator and patient must wear certified laser-protective goggles appropriate for the used wavelength.
Stop the device and seek urgent ophthalmologic assessment. Inform the examiner of the used wavelength and the possibility of Class 4 laser exposure up to 6 W. Lack of symptoms does not exclude injury.
Laser is not electrical stimulation, so pacemakers do not present the same automatic risk as in electrotherapy. For implanted electronic devices, severe heart disease or thoracic treatment, follow the manufacturer’s manual and obtain treating physician approval.
The package includes an 808 nm handpiece according to the source. 980 and 1064 nm handpieces are optional and are not part of the standard package.
Their optical power is identical. The 6.0 is portable and smaller; the Pro is a desktop unit with a larger display for fixed clinic workstations.
There is no fixed number of sessions valid for all indications. Course length should be determined by diagnosis, tissue condition, dose, clinical response and rehabilitation plan.
What does the package include?
- 1 pc PhysioLaser 6.0 portable central unit
- 1 pc 808 nm handpiece with 11 mm optic
- 1 pc operator laser-protective goggles
- 1 pc patient laser-protective goggles
- 1 pc power adapter
- 1 pc rechargeable battery
- 1 pc safety emergency stop
- 1 pc padded carrying case
- 1 pc user manual
The goggles in the package are intended for use with the standard 808 nm handpiece. For optional 980 or 1064 nm handpieces, check that the goggles’ protection range and optical density are appropriate for the given wavelength.
Protect the optical surface from scratches, dust and oily contamination. Clean only with materials and methods permitted in the user manual.
Do not use the device if the handpiece, cable, connector, goggles or optical surface are damaged.
Which professional PhysioLaser fits your clinic?
Technical specifications
| Laser type | GaAlAs diode laser |
| Standard wavelength | 808 nm with the handpiece included in the package |
| Optional wavelengths | According to the source, 980 and 1064 nm handpieces may also be available; sold separately |
| Maximum optical power | 6 W, manufacturer tolerance: ±20% |
| Maximum theoretical energy delivery | 360 Joules per minute at maximum continuous output |
| Laser class | Class 4, CEI EN 60825-1 |
| Emission modes | Continuous and pulsed |
| Maximum frequency | 10,000 Hz |
| Base optic | 11 mm diameter, approximately 0.95 cm² treatment spot |
| Optional optic | According to the source, a 22 mm optic of about 3.8 cm² may also be available |
| Programs | Approximately 85 preset clinical protocols |
| Display | 2.6-inch backlit LCD |
| Power supply | Power adapter and rechargeable battery |
| Dimensions | 100 × 160 × 35 mm |
| Weight | Approximately 450 grams |
| Design | Portable |
| Medical classification | CE MDD, Class IIb medical device |
| SKU | G5740 |
| Manufacturer | Globus Italia, Italy |
When not to use the device?
- Never direct the laser beam into the eye or the immediate eye area.
- Do not apply to the abdomen or pelvic area during pregnancy.
- Only use over malignant tumors with the explicit approval of the treating physician.
- Do not use over active bleeding or areas with significant bleeding tendency.
- For photosensitivity or photosensitizing medication, obtain prior medical consultation.
- Postpone treatment in febrile or acute general illness.
- Do not treat directly over the thyroid and other endocrine glands.
- Investigate unknown swelling, pain or skin lesions before treatment.
For implanted electronic devices, severe heart disease or thoracic treatment, follow the full manufacturer manual and obtain medical approval. Detailed safety information →
Important information
The PhysioLaser 6.0 is intended as an adjunctive treatment. It does not replace diagnosis, medical treatment, physiotherapy or appropriate rehabilitation.
Due to its Class 4 classification it must be used only by trained professionals in an appropriate laser safety environment. Higher power enables faster dose delivery but, with incorrect parameters, increases the risk of excessive dosing and tissue heating.
The product description is for informational purposes and does not constitute personalized medical advice or laser-safety training. Referenced studies are not device-specific evidence.
Scientific background
High-power laser therapy has been studied in several musculoskeletal conditions. Studies used varying wavelengths, powers, doses and treatment protocols, so their results cannot be automatically transferred to all PhysioLaser programs.
-
Ahmad MA et al. (2021):
Effects of low-level and high-intensity laser therapy as adjunctive to rehabilitation exercise on pain, stiffness and function in knee osteoarthritis: a systematic review and meta-analysis.
Physiotherapy.
PubMed
Systematic review in knee osteoarthritis. -
Abdildin Y et al. (2023):
High-intensity laser therapy in low back pain management: a systematic review with meta-analysis.
Lasers in Medical Science.
PubMed
Systematic review in low back pain. -
Barassi G et al. (2021):
Dual-wavelength high-power laser therapy and neuromuscular manual therapy in chronic neck pain: a randomized clinical trial.
Journal of Biological Regulators and Homeostatic Agents.
PubMed
Randomized trial in chronic neck pain with differing device protocols. -
Mostafa MSEM et al. (2022):
Effect of High-Power Laser Therapy Versus Shock Wave Therapy on Pain and Function in Knee Osteoarthritis Patients.
Photobiomodulation, Photomedicine, and Laser Surgery.
PubMed
Comparison of high-power laser and shock wave therapy in knee osteoarthritis. -
Verma S et al. (2022):
Effectiveness of High Power Laser Therapy on Pain and Isokinetic Peak Torque in Athletes with Proximal Hamstring Tendinopathy.
BioMed Research International.
PubMed
Study in athletes with proximal hamstring tendinopathy.
Looking for a portable, higher-power professional laser?
6 W output, around 85 protocols, battery operation and an approximately 450 g portable central unit.
Soft-laser therapy – comprehensive guide →
PhysioLaser 6.0 – portable 6 W model →
PhysioLaser 6.0 Pro – desktop 6 W model →
PhysioLaser 12.0 – higher-power model →
Soft-laser contraindications and safety information →