What treatments can it be used for?
The program library provides starting points for adjunctive treatment of arthrosis, knee osteoarthritis, knee pain, hip pain, ankle sprain, bursitis and other periarticular complaints.
Photobiomodulation can be used to influence pain and complaints of surrounding soft tissues. It does not restore worn cartilage, meniscus or ruptured ligaments, and it does not replace physiotherapy, load modification or orthopedic evaluation.
Manufacturer protocols include acute and chronic back pain, lumbar and cervical syndromes, myofascial pain and radiculopathy-related complaints.
Program names do not replace diagnosis. For radiating limb pain, muscle weakness, sensory disturbances, urinary or fecal dysfunction, trauma or rapid deterioration, medical examination is required before treatment.
The program library may include protocols for shoulder pain, frozen shoulder, subacromial bursitis, rotator cuff-related complaints and postoperative rehabilitation.
The laser is an adjunct in rehabilitation. Significant strength loss, post-injury immobility or suspicion of complete tendon rupture requires imaging and specialist evaluation.
Epicondylitis, Achilles tendinopathy, patellar tendon complaints, De Quervain syndrome, tenosynovitis and trigger point treatment are among the target areas listed above.
Tendon rehabilitation is based on load management and progressive strengthening. Pain reduction alone does not mean the tendon is ready for full sport or work load.
For muscle pain, contracture, contusion, strain, post-injury edema and postoperative rehabilitation, the laser can be part of a comprehensive treatment plan.
In acute injuries, first exclude fracture, complete rupture, infection and other urgent conditions. High power is not intended to mask symptoms that prevent return to sport.
The plantar fasciitis program provides a manufacturer starting point for targeted treatment of painful areas of the plantar fascia.
The laser does not remove a bony heel spur. The aim is adjunctive treatment of surrounding soft tissue complaints alongside load modification, appropriate footwear and rehabilitation.
The program list includes edema-management protocols for acute injuries and postoperative states.
Unknown-origin swelling should be investigated first. The laser does not replace compression, movement, appropriate wound care or comprehensive lymphedema therapy.
The 12 W models’ program library includes scar treatment and other dermatologic-targeted programs. Their applicability depends on the connected handpiece, its wavelength and the manufacturer protocol.
Do not treat infected, oozing, rapidly changing or unknown-origin skin lesions without a diagnosis. Pigmented lesions, suspected melanoma or active cancer are contraindications or require specialist decision.
Why choose the PhysioLaser 12.0?
12 W maximum optical power
At maximum continuous operation up to 720 Joules per minute can be delivered. Compared to a 6 W model, the same energy dose can theoretically be achieved in half the time.
100 built-in clinical protocols
The program library offers manufacturer starting points for musculoskeletal, sports rehabilitation, edema-related and skin/scar treatments.
11 and 22 mm optics included
The smaller optic is for targeted point treatment; the larger optic (~four times the area) is useful for faster scanning of larger surfaces.
Portable central unit of about 404 grams
The 12 W output is combined with a compact, battery-powered design, making it usable in sports clubs, multi-site clinics or mobile practice.
808 nm standard, optional 980 and 1064 nm
The base package includes an 808 nm handpiece. The 980 and 1064 nm handpieces are optional accessories; the 1064 nm handpiece has a maximum power of 3 W.
Two protective glasses and emergency stop
Operator and patient laser-protective glasses required for Class 4 treatments, and a safety emergency stop, are included in the package.
Is the PhysioLaser 12.0 right for you?
100 built-in clinical protocols
The program library mainly covers musculoskeletal, sports rehabilitation, edema-related and dermatologic treatment goals. Program selection eases setup but does not replace diagnosis, dose verification or documentation of the treatment.
Arthrosis, osteoarthritis, knee, hip and ankle complaints, bursitis, peri-meniscal complaints and postoperative or post-injury joint rehabilitation.
Program names do not replace diagnosis. Exact parameters must be checked in the device menu and the user manual.
Acute and chronic back pain, lumbar and cervical syndromes, radiculopathy-related pain, myofascial complaints and postoperative rehabilitation.
Program names do not replace diagnosis. Exact parameters must be checked in the device menu and the user manual.
Shoulder pain, frozen shoulder, rotator cuff-related complaints, epicondylitis, Achilles and patellar tendinopathies, tenosynovitis and trigger points.
Program names do not replace diagnosis. Exact parameters must be checked in the device menu and the user manual.
Muscle pain, DOMS, contracture, contusion, strain, post-injury or postoperative edema, rehabilitation phases and adjunctive pain management.
Program names do not replace diagnosis. Exact parameters must be checked in the device menu and the user manual.
The library may include skin-regeneration, scar treatment and other dermatologic-targeted programs. Availability depends on the connected 808, 980 or 1064 nm handpiece.
The source material mentions 27 dermatology programs. Some of these are available only with the appropriate optional handpiece connected.
Program names do not replace diagnosis. Exact parameters must be checked in the device menu and the user manual.
Important: the base package includes an 808 nm handpiece. Using 980 or 1064 nm programs requires the appropriate optional handpiece and eye protection covering the given wavelength.
What does 12 W laser treatment mean?
Photobiomodulation delivers light of a specific wavelength and dose to the treated tissue. The biological response depends on wavelength, power, energy dose, spot size, pulse settings and treatment geometry.
12 W maximum power in continuous mode corresponds to 12 Joules per second, or up to 720 Joules per minute. This enables fast dose delivery but requires increased attention to avoid tissue heating and excessive dosing.
The standard 808 nm handpiece operates in the near-infrared range. Optional 980 and 1064 nm handpieces may offer different tissue absorption characteristics, but they should not be simplistically ranked as “deeper” or automatically more effective wavelengths.
The main clinical advantage of higher power is throughput. It does not automatically mean stronger biological effect, faster healing or fewer treatment sessions required for a course.
Professional treatment in four steps
Examine the patient
Clarify the diagnosis, treatment goal, tissue condition and contraindications. Program names must not be used as diagnosis.
Select the handpiece, optic and protocol
Check wavelength, power, mode, frequency, duty cycle, treatment time, spot size and the size of the area to be treated.
Ensure a Class 4 environment
The operator and patient must wear appropriate certified laser-protective eyewear for the used wavelength. Remove reflective objects, prevent unauthorized entry and keep the emergency stop accessible.
Perform and document the treatment
For point treatment keep the head stable; for scanning move at an even speed. Document the area, handpiece, optic, parameters, energy dose and patient response.
Frequently asked questions
12 W is the maximum rated optical power. At maximum continuous operation this corresponds to up to 720 Joules per minute. For pulsed programs the average energy delivered may be lower.
No. The main advantage of higher power is faster dose delivery. Penetration is also determined by wavelength, tissue optical properties, spot size, contact and treatment geometry.
Yes. The device is a Class 4 laser. Both operator and patient must wear certified laser-protective eyewear appropriate for the used wavelength.
Stop the device and seek urgent ophthalmologic assessment. Inform the examiner of the used wavelength and the possible exposure to a Class 4 laser of up to 12 W. Lack of symptoms does not exclude injury.
No. According to the source material the base package includes the 808 nm handpiece. The 980 and 1064 nm handpieces are optional accessories; the 1064 nm head has a maximum power of 3 W.
The 11 mm optic is practical for smaller, targeted areas; the 22 mm optic is useful for scanning larger surfaces. Because of the larger spot size, power density and required treatment time may differ.
The optical power is identical. The portable 12.0 is smaller and more mobile; the 12.0 Pro is a desktop design with a larger display and five additional manufacturer programs.
There is no fixed number of sessions valid for all indications. Course length should be determined by diagnosis, tissue condition, dose, clinical response and the rehabilitation plan.
What does the package include?
- 1 pc PhysioLaser 12.0 portable central unit
- 1 pc 808 nm handpiece with 11 mm optic
- 1 pc 22 mm optic for the 808 nm handpiece
- 1 pc operator laser-protective glasses
- 1 pc patient laser-protective glasses
- 1 pc power adapter
- 1 pc rechargeable battery
- 1 pc safety emergency stop
- 1 pc padded carrying case
- 1 pc user manual
According to the source the 11 mm optic creates approximately a 0.95 cm² spot and the 22 mm about 3.8 cm². The smaller head is for targeted point treatment; the larger is practical for scanning shoulders, thighs, back or other larger surfaces.
The larger spot spreads the same power over a larger area, so power density and treatment time cannot be transferred automatically between optics.
The glasses included are intended for standard use with the 808 nm handpiece. For optional 980 or 1064 nm handpieces check that the glasses’ protection range and optical density are appropriate for the wavelength used.
Protect the optical surface from scratches, dust and oily contamination. Clean only with materials and methods permitted in the user manual.
Do not use the device if the handpiece, cable, connector, glasses or optical surface are damaged.
Which professional PhysioLaser suits your practice?
Technical specifications
| Laser type | GaAlAs diode laser |
| Standard wavelength | 808 nm with the handpiece included in the package |
| Optional wavelengths | 980 nm handpiece and 1064 nm handpiece up to 3 W; optional accessories |
| Maximum optical power | 12 W, manufacturer tolerance: ±20% |
| Maximum theoretical energy delivery | 720 Joules per minute at maximum continuous power |
| Power adjustment | According to the source, in 0.5 W steps |
| Laser class | Class 4, CEI EN 60825-1 |
| Emission modes | Continuous and pulsed |
| Maximum frequency | 10,000 Hz |
| Small optic | 11 mm diameter, approximately 0.95 cm² treatment spot |
| Large optic | 22 mm diameter, approximately 3.8 cm² treatment spot |
| Programs | 100 pre-set clinical protocols |
| Dermatology programs | According to the source 27 programs; usability depends on the connected handpiece |
| Display | 2.6-inch backlit LCD |
| Power supply | Power adapter and rechargeable battery |
| Dimensions | 100 × 160 × 35 mm |
| Weight | Approximately 404 grams |
| Design | Portable |
| Medical device classification | According to the source CE-marked, class IIb medical device |
| SKU | G5741 |
| Manufacturer | Globus Italia, Italy |
When should you not use the device?
- Never point the laser beam at the eye or the immediate area around the eye.
- Do not apply to the abdomen or pelvic area during pregnancy.
- Do not use directly over malignant tumors except with explicit permission from the treating physician.
- Do not use over active bleeding or areas with significant bleeding tendency.
- In photosensitivity or when using photosensitizing drugs, obtain prior medical consultation.
- Postpone treatment in febrile or acute general illness.
- Do not treat directly over the thyroid or other endocrine glands.
- Unknown-origin swelling, pain or skin lesion requires investigation first.
For implanted electronic devices, severe heart disease or chest treatments follow the full manufacturer manual and obtain medical approval. Detailed safety information →
Important information
The PhysioLaser 12.0 is intended as an adjunctive treatment. It does not replace diagnosis, medical treatment, physiotherapy or appropriate rehabilitation.
Due to its Class 4 classification it must be used only by trained professionals in an appropriate laser safety environment. Higher power enables faster dose delivery but, if parameters are set incorrectly, increases the risk of excessive dosing and tissue heating.
The product description is for informational purposes and does not constitute personalized medical advice or laser safety training. Cited studies are not device-specific evidence.
Scientific background
High-power laser therapy has been studied in several musculoskeletal conditions. Studies used varying wavelengths, powers, doses and protocols, so their results cannot be automatically transferred to all PhysioLaser programs.
-
Ahmad MA et al. (2021):
Effects of low-level and high-intensity laser therapy as adjunctive to rehabilitation exercise on pain, stiffness and function in knee osteoarthritis: a systematic review and meta-analysis.
Physiotherapy.
PubMed
Systematic review in knee osteoarthritis. -
Abdildin Y et al. (2023):
High-intensity laser therapy in low back pain management: a systematic review with meta-analysis.
Lasers in Medical Science.
PubMed
Systematic review in low back pain. -
Barassi G et al. (2021):
Dual-wavelength high-power laser therapy and neuromuscular manual therapy in chronic neck pain: a randomized clinical trial.
Journal of Biological Regulators and Homeostatic Agents.
PubMed
Randomized trial in chronic neck pain with different device protocols. -
Mostafa MSEM et al. (2022):
Effect of High-Power Laser Therapy Versus Shock Wave Therapy on Pain and Function in Knee Osteoarthritis Patients.
Photobiomodulation, Photomedicine, and Laser Surgery.
PubMed
Comparison of high-power laser and shock wave in knee osteoarthritis. -
Verma S et al. (2022):
Effectiveness of High Power Laser Therapy on Pain and Isokinetic Peak Torque in Athletes with Proximal Hamstring Tendinopathy.
BioMed Research International.
PubMed
Study in athletes with proximal hamstring tendinopathy.
Looking for a portable flagship for high treatment throughput?
12 W power, 100 programs, two optics, battery operation and a central unit of about 404 grams.
Soft laser therapy – comprehensive guide →
PhysioLaser 6.0 Pro – desktop 6 W model →
PhysioLaser 12.0 – portable 12 W model →
PhysioLaser 12.0 Pro – desktop 12 W model →
Soft laser contraindications and safety information →
Soft laser devices – full range →